PNACHO-D 1600: 1600 kVA cast-resin dry-type transformer, 21/0.42 kV, Dyn11, class F, C3/E3/F1, Ecodesign Tier 2 (P0 ≤ 1980 W, Pk ≤ 13000 W). CE, routine-tested, 5-year warranty, delivery across Europe.

High voltage
Low voltage
Vector group
Dyn11 standard
No-load losses P01980 W
Load losses Pk (75 °C)13000 W
= Tier 2 limit · (EU) 2019/1783uk 6 %
Standard configurations available from stock · delivery to any EU country
Data sheet PDF
Delivered with routine test report, EU declaration of conformity, rating plate and operating manual. 60-month warranty.

The PNACHO-D 1600 is a three-phase, vacuum-cast epoxy-resin dry-type transformer for 21 kV networks in buildings and industrial plants where fire safety matters: self-extinguishing class F1, climatic class C3 and environmental class E3 to IEC/EN 60076-11. It complies with Ecodesign Tier 2 – Regulation (EU) 2019/1783 – and needs no oil, no bund and no fire-suppression system.

Technical data

Rated power1600 kVA
High voltage21 kV
Low voltage0.42 kV
Vector groupDyn11
Tapping range±2 × 2.5 % (5 positions), off-circuit
Frequency50 Hz
CoolingAN (AF +40 % on request)
No-load losses P0≤ 1980 W
Load losses Pk (75 °C)≤ 13000 W
Short-circuit impedance uk6 %
Sound power level LWA52 dB(A)
Insulation level HV (LI/AC)LI 125 / AC 50 kV
Dimensions L × W × H1695 × 1000 × 2100 mm
Total mass≈ 4000 kg
WindingsAluminium, vacuum-cast epoxy (copper on request)
Protection / finishIP00 indoor (IP21–IP44 enclosure on request), class C3/E3/F1, insulation class F
StandardsIEC/EN 60076-11, EN 50588-1, EN 50708, (EU) 2019/1783, CE (LVD, EMC, RoHS)
Efficiency classEcodesign Tier 2 – (EU) 2019/1783
Warranty60 months

Standard equipment

Vacuum-cast epoxy HV windings, aluminium foil LV windings
Grain-oriented, step-lap core with anti-corrosion coating
Off-circuit tapping links ±2 × 2.5 %
3 × PT100 sensors in LV windings + temperature monitoring relay T-154
Bi-directional rollers, lifting lugs, earthing terminals
Rating plate and wiring diagram, EU energy label
Partial discharge ≤ 10 pC

Options on request

Copper windings (Cu/Cu)Enclosure IP21 – IP44Forced-air cooling AF (+40 % power)Low-voltage 0.4 kV or 0.69 kVVector group Dyn5Dual-voltage HV winding (e.g. 10/21 kV)Anti-vibration pads, surge arrestersEnclosure temperature sensors and fan control

Documents

Technical data sheet · PNACHO-D 1600 kVAPDF
The routine test report of the individual unit is sent with the delivery.

Testing and conformity

Every unit undergoes routine tests to IEC 60076: no-load loss and current, load loss and impedance at 75 °C, winding resistance, voltage ratio and vector group, induced and applied voltage withstand, insulation resistance. Type tests (lightning impulse, temperature rise, short-circuit withstand, sound level) are available on request. Each transformer is delivered with test report, EU declaration of conformity (CE – LVD, EMC, RoHS, Ecodesign) and operating manual.

Applications

Hospitals, data centres, shopping centres, high-rise and public buildings, tunnels and underground installations, industrial halls, indoor substations.